Nonresidential ACM

6.5 Nonresidential ACM Manual Kitchen Space Type: In order for compliance software to analyze this and other kitchen related measures, kitchens shall be modeled as separate space types apart from other building occupancy types and be assigned lighting, plug load, and people densities. Internal load shall use the following:  Lighting: 1.6 watts per square foot  Plug Load: 10 watts per square foot  Occupants: 100 square feet per occupant  Schedules: Use Table N2-8-Nonresidential Occpancy Schedules(Other than Retail) User Input: 1. Values for all Type I and Type II exhaust hoods in the modeled kitchen. a. CFM values for all hoods b. For Type I hoods ONLY i. Hood Length ii. Hood Style (Canopy, Wall Mount, etc.) iii. Hood Cooking Duty (Highest duty appliance under hood)